Description
IllustraFlex firmware 3.1.4 returns http 500 from the http metedata request. The camera failed to respond to a motion/input trigger event. This is a fw issue and is fixed in 3.1.5 archived here.
\\shares.exacq.org\Public\Software\American Dynamics\Illustra Flex firmware\web-update-Ver.3.1.5-20170213.opk.
<br>
Version Introduced
8.2.2.108683
<br>
Platform
All
<br>
Steps to reproduce
- Connect illustrFlex(ADCi600F/ADCi800F) that supports iAPI3(fw > 3.0.14) to illustra3 plugin.
<br>
Expected result
- Camera connected and events works as expected.
<br>
Actual result
- Motion/trigger event failed and return http error 500.
<br>
Work Around
- Revert to earlier supported fw(3.0.14)
<br>
Version Fixed
Camera firmware 3.1.5