Description When connecting to a web service whose initialization fails, all servers should be disabled. <br> Version Introduced 8.0 <br> Platform All <br> Steps to reproduce Add a web service that causes initialization to fail. <br> Expected result The enable toggles for each server on the web service is disabled. <br> Actual result The enable… Continue reading Servers are able to be enabled if Web Service initialization fails
Tag: Level2
Samsung PTZ functionality loss in exacqVision Server 20.03
Issue Samsung PTZ functionality loss in exacqVision Server 20.03 <br> Workaround Re-enable mechanical PTZ for the camera, via exacqVision Client. <br> Version Affected 20.03 <br> Version Fixed Fixed in 20.03.111 and forthcoming 20.03.7 RC
Enterprise Manager Cannot select all servers for license transfer
Issue When a user has more than 100 servers, there’s is an issue with filtering and selecting any servers that are not initially displayed. <br> Version Affected 20.03.2.0 <br> Version Fixed 20.03.110
Honeywell Vista 128bpt Incorrect Bypass Status
Issue An issue was found with our Honeywell Vista Security Integrations plugin and the Honeywell Vista 128bpt panel where the zone bypass button was not functioning for some combinations of zone status. Each zone is capable of having up to 16 different states simultaneously. For example, a zone may be in a state of both… Continue reading Honeywell Vista 128bpt Incorrect Bypass Status
Analog PTZ may exhibit significant lag with exacq joystick and Sensormatic matrix switches
Issue This issue is especially pronounced when manually performing proportional PTZ via exacq joystick and exacqVision Client, with Server versions <= 19.06. Once user releases joystick, a camera may take up to 20 seconds to stop. <br> Version Fixed Fixed in 19.09 RC exacqVision Server
Server 19.06 indicates failover/failback not supported
Issue Enterprise Manager will report that failover not supported on some instance of exacqVision server 19.06. This affects only fresh installs of 19.06 and applicable to all platforms. <br> Workaround Downgrade-UpgradeDowngrade the server to 19.03, then upgrade the server to 19.06. This issue does not affect upgraded systemsManual xml editstop the exacqServer serviceedit update.xml file… Continue reading Server 19.06 indicates failover/failback not supported
Additional Linux resources needed for larger installations
Description Crashes found during restarts were traced back to insufficient file descriptors.On larger installations we need to tune the linux server by allowing more file descriptors for our process.The problem has been seen on systems with as few as 117 streams when storage rules are in effect. <br> Version Introduced From beginning, scaleability issue. <br>… Continue reading Additional Linux resources needed for larger installations
RTSP library crashes with invalid h264 packet from camera
Description Rtsp_lib is a layer of code that interface with Live555 for streaming video/audio/metadata and the camera plugins Axis/Dahua(essentials)/illusta3/illustraFlex/Hikvision(e-series)/Samsung/Panasonic/Sony/IQEye/UDP/RTSP/Pelco). We have seen an issue with Pelco Optera and IllustraFlexcameras that emit either larger than allocated userdata or 0 length sps packets and caused the server to crash. This is not very common but need to… Continue reading RTSP library crashes with invalid h264 packet from camera
Toggling a Web Service Connection Multiple Times Can Cause Failed Initialization
Description Enabling and then Disabling a Web Service multiple times within Exacq Mobile 3 during the connection process can prevent the servers from being retrieved. <br> Version Introduced <br> Platform Mobile-All <br> Steps to reproduce <br> Expected result The Server List is displayed <br> Actual result The Text ‘Unable to retrieve servers’ is displayed <br>… Continue reading Toggling a Web Service Connection Multiple Times Can Cause Failed Initialization
Pressing the Web Service Edit Dialog Apply button twice make the Apply button unable to be clicked
Description After attempting to add an already added web service if the Apply button is clicked twice it will be unable to be clicked again until all the text is removed from the input. <br> Version Introduced Exacq Mobile 3, version 8.0.0 <br> Platform Mobile-All <br> Steps to reproduce <br> Expected result The Apply Button… Continue reading Pressing the Web Service Edit Dialog Apply button twice make the Apply button unable to be clicked