Categories
Knowledge Support Support Categories Products exacqVision Integrations

Illustra3 with illustraFlex fw 3.1.4 returns http error 500

Description

IllustraFlex firmware 3.1.4 returns http 500 from the http metedata request. The camera failed to respond to a motion/input trigger event. This is a fw issue and is fixed in 3.1.5 archived here.

\\shares.exacq.org\Public\Software\American Dynamics\Illustra Flex firmware\web-update-Ver.3.1.5-20170213.opk.

<br>

Version Introduced

8.2.2.108683

<br>

Platform

All

<br>

Steps to reproduce

  • Connect illustrFlex(ADCi600F/ADCi800F) that supports iAPI3(fw > 3.0.14) to illustra3 plugin.

<br>

Expected result

  • Camera connected and events works as expected.

<br>

Actual result

  • Motion/trigger event failed and return http error 500.

<br>

Work Around

  • Revert to earlier supported fw(3.0.14)

<br>

Version Fixed

Camera firmware 3.1.5