Categories
Knowledge Support Support exacqVision Server Categories Products

Acti Motion Windows Disappear exacqVision Server 21.12.2.0 and 22.03.1

Title

Acti Motion Windows Disappear exacqVision Server 21.12.2.0 and 22.03.1 Windows Disappear exacqVision Server 21.12.2.0  

Description 

After restarting exacqVision Server service Acti motion windows are no longer present, exacqVision Server versions 21.12.xx and 22.03.1  

Product 

exacqVision Server  

Steps to Reproduce 

  • Update to exacqVision Server 22.03.1
  • Verify motion windows are present on the Motion tab of the cameras configuration page 
  • Stop and start the exacqVision Server service
  • Go back to the motion tab on the cameras configuration page 

Expected Results 

  • Motion windows are as they were before the service restart

Actual Results 

  • Motion windows are gone 

Solution

Motion still records but a rollback to exacqVision Server Version 21.09.xx is required in order to see the motion windows.    Models Known to exhibit this issue:

  • ACM3401
  • ACM5601
  • D52
  • D55
  • E53
  • E54
  • E56
  • E77

  This issue will be fixed in exacqVision Server 22.03.2 or higher