Request was denied by the device. Make sure the correct credentials have been entered Description With Axis firmware 5.70 and later with encryption mode enabled, an Axis device could take up to five minutes (the default setting for IP reconnection in exacqVision) to start streaming. Notes Workaround: Wait for the IP reconnection period to elapse… Continue reading Request was denied by the device. Make sure the correct credentials have been entered
Category: exacqVision Server
*** EDESTUNREACH – 113 ***
*** EDESTUNREACH – 113 *** Description Destination unreachable (ICMP). Notes This error occurs when an ICMP destination unreachable packet for the socket is received.
*** ECONNREFUSED – 111 ***
*** ECONNREFUSED – 111 *** Description Connection refused. Notes This error can occur during an attempt to connect a TCP socket. It is reported when a reset or an unexpected SYNC message is received.
board *** watchdog expired
board *** watchdog expired Description The heartbeat communication to the capture board has timeout. The system will reboot. Notes Could be a hardware problem or anti-virus interference. Also possible if no page file is enabled.
*** – only enterprise systems allow directory integration.
*** – only enterprise systems allow directory integration. Description The current license key is Start or Professional, but the current configuration is trying to use LDAP. Notes This can happen if a Start/Professional license is applied to a previously Enterprise system. Or if the exacqVision Client is attempting to use SSO to connect to a… Continue reading *** – only enterprise systems allow directory integration.
***EADDRINUSE – 102 ***
***EADDRINUSE – 102 *** Description Another socket is already bound to the address specified in bind
Failed to set time server registry value ***.
Failed to set time server registry value ***. Description The Windows registry could not be updated with the listed information. Notes Likely permissions related. Group Policy may be disallowing changes.
*** EADDRNOTAVAIL – 101 ***
*** EADDRNOTAVAIL – 101 *** Description Endpoint address not available. This error occurs when a match for the requested address is not found in the routing table.
*** WSAEHOSTUNREACH – 10065 ***
*** WSAEHOSTUNREACH – 10065 *** Description No route to host. Notes A socket operation was attempted to an unreachable host. See WSAENETUNREACH.
Failed to process IPC message from core – ***
Failed to process IPC message from core – *** Description Low level error indicating a corrupted installation, or anti-virus interference. Notes