Categories
Software Downloads Software Categories exacqVision Server Windows x64 exacqVision Server Categories Products

ExacqVision Server Windows x64 v24.09.5.0

Q3 2024-09-19 ev-Server-Windows-x64^Version 24.09.5.0^https://cdnpublic.exacq.com/24.09/exacqVisionServer_24.09.5.0_x64.exe^21 October 2024^148MB,

Q3 2024-09-19 ev-Combo-Windows-x64^Version 24.09.7.0^https://cdnpublic.exacq.com/24.09/exacqVision_24.09.7.0_x64.exe^21 October 2024^361MB,

Categories
Software Categories exacqVision Client Windows msi x64 exacqVision Server Windows exacqVision Client MacOS arm64 exacqVision Server Linux exacqVision Server Windows x64 exacqVision Server Linux x64 exacqVision Client Linux x64 exacqVision Client Linux exacqVision Client Windows msi exacqVision Client Windows x64 exacqVision Client MacOS Software Categories exacqVision Client Windows Knowledge Support Support exacqVision Client exacqVision Server Categories Products

Performance issue when analytics enabled on Exacq

Description 

issues with analytics enabled where-as the server will eventually become unresponsive and reboot after a short time.

Product

ExacqVision Server versions 23.09 & 24.03 & 24.06

Steps to Reproduce 

1) install 23.09.9.0 exacqvision server software
2) connect illustra Pro4 20mp IPS20-M12-OIA4 using firmware SS017.06.05.00.008
3) Verify analytics are enabled on the cameras – analyticmetadata, objectdetection, motiondetection
4) verify maximum days to keep events is configured for 30 days
5) verify maximum days to keep bounding box metadata is configured for 1 day
6) Allow the system to run over a period of time and observe D

Expected Results 

ExacqVision server and software should continue to run normally as expected.

Actual Results 

ExacqVision server and software will continue to consume resources until the system needs to reboot, while displaying acquiring video status on camera live panels and filling up OS drive with eventpi.db file.

Solution

Update ExacqVision server and Client to 24.09

Categories
Knowledge Support Support exacqVision Enterprise exacqVision Client exacqVision Server exacqVision Mobile exacqVision Webservice Categories exacqVision Hardware Products

2024-09 September Quarterly Release Training

<br>

exacqVision Server

  • Bug Fix – Fixed insertion of objects lacking metadata or bounding box
    (AESW-9440)
  • Bug Fix – Improvements to event size estimates for bookmarks
    (AESW-11010)
  • Bug Fix – illustra3 and illustramultipi fixed issue where Alarm 2 status would not change after being canceled
    (AESW-10146)
  • Bug Fix – illustra3 and illustramultipi fixed issue causing edgestor backfill to hang
    (AESW-9581)
  • Bug Fix – Onvif, fixed issue preventing simultaneous PTZ
  • Big Fix – Onvif, fixed excessive pullpoint logs on errors
    (AESW-10727)
  • Bug Fix – Onivf, fixed potential PTZ disconnects
    (AESW-11469)
  • Bug Fix – psfpi, fixed potential hang when evAPI attempts to cancel search
    (AESW-10961)
  • Bug Fix – Samsungpi, fixed crash on disabled device during connection
  • Bug Fix – Samsungpi, fixed potential crash when connecting to newer devices
  • Enhancement – Support Area Zoom on Axis M5000-G PTZ camera
    (AESW-10568)
  • Enhancement – eventpi, new event indicates thinning occurred, includes event linking sources
    (AESW-7651)
  • Enhancement – Installer adds firewall rules added for failover and failback
  • Enhancement – Improved analytic parsing
  • Enhancement – Provide the analytic type to core
  • Enhancement – Improved handling of transport errors
    (AESW-10120)
  • Enhancement – New SOAP calls for Onvif Profile M and S conformance
  • Enhancement – remotepi, move connection to production switchboard service
    (AESW-9771)
  • Enhancement – Additional logging around LDAP reauth queries
    (AESW-9769)
  • Enhancement – Improved performance by reducing amount of analytics sent from server to client
    (AESW-7715)
  • Feature – Support for Wasabi S3 as archiving target
    (AESW-5814, AESW-10924)
  • Feature – Support added for Axis Thermometry
    (AESW-8816, AESW-8918)
  • Feature – Illustra LPR Support
    (AESW-6504)

exacqVision Client

  • Bug Fix – Manage the preferred MAC address in License panel
    (AESW-11267)
  • Bug Fix – Fixed issue where exacqReply controls did not appear until window was resized
    (AESW-9992)
  • Bug Fix – Clear grid dropdown, to fix issue where drop-down menus duplicate entries
    (AESW-10923)
  • Bug Fix – Fixed issue with Oldest Desired Content of Cloud Drive
    (AESW-8097)
  • Bug Fix – Fixed issue of event forward button being disabled when skipping ahead
    (AESW-8958)
  • Bug Fix – Fixed issue of client crash when selecting Find Camera when creating a new View
    (AESW-10038)
  • Bug Fix – Fixed client crash when selecting audio in Add Video panel
  • Bug Fix – Fixed issue of auto play not working in Timeline search
    (AESW-8529)
  • Enhancement – Remote Connections, found on navigation tree
  • Enhancement – Added Mobile Optimized Streaming panel for Remote Connections
  • Enhancement – New toast message indicating event thinning has occurred
    (AESW-9871)
  • Enhancement – Client improvements to amount of analytic data passed between server/client
    (AESW-7716)
  • Enhancement – Support “horizontal flip” for Storage page to accommodate storage layout for new Avnet systems
    (AESW-10562)
  • Enhancement – Apply our security standards to Bodyworn password fields
    (AESW-1575)
  • Feature – Support for Wasabi S3 as archiving target
    (AESW-11025)

exacqVision Web Service

  • Bug Fix – Fixed 24.03 issue where iPAD experienced video buffering and timeout errors
    (AESW-10945, AES-839, AES-863, AES-909)
  • Bug Fix – Web client supports session timeout detection, respects the login token
    (AESW-9753, AES-774)

exacqVision Enterprise Manager

  • Bug Fix – Add missing pagination endpoints
  • (AESW-11414)

Exacq Mobile 3

  • Bug Fix – Fixed issue with video failing to play after one hour
  • Enhancement – Added notification to point users to new exacqVision Mobile app
    (AESW-9166)

exacqVision Mobile

  • exacqVision Mobile requires Server version 24.09 or higher
  • Remote Connectivity requires Client 24.09 or higher as the Client is needed to connect to the cloud switchboard and generate access codes
  • If SSA expiration or OS requirements prevent updating to Server 24.03, users will need to continue using Exacq Mobile 3, with the exacqVision Web Service

Exacq Hardware

Hardware Revisions

  • C-Series 16S & 32S
  • G-Series Micro
  • G-Series PoE 8ch & 16ch
  • Q-Series Desktop & Desktop Hybrid
  • A-Series 2A & 2A Hybrid  (no RAID)
  • A-Series FA & FAR  (RAID)
  • X-Series 1U & 2U  (RAID)

exacqVision Advantage

  • Provides free exacqVision licensing on BBE hardware for most models of Illustra Flex and Pro cameras (Gen3, Gen4, and future generations).
  • Does not apply to the Flex Gen3 Multisensor, which is ONVIF only, does not have the Illustra API

Illustra

  • New Pro camera models providing LPR on the edge
    • Bullet IPS05-B12-LPR4
    • Dome IPS05-D12-LPR4

<br>

Categories
Knowledge Support Support exacqVision Server Products

PSMOVE For Windows

Description 

The purpose of this KB is to help run PS MOVE and where to place the files on a system.

Product 

PSMOVE.exe
Exacq Server 23.03 and above.

File Location: 

Windows:
Place psmove.exe in the Server folder.
Open powershell or command promt as ADMIN.
cd C:\Program Files\exacqVision\Server and place the psmove.exe into the server folder.

Linux: ETA not available yet.

NOTE: When Running on Windows AND Linux PSMOVE must be in the sever folder because it depends on the libraries installed with server.

Running PSmove on Windows: 

Once the psmove.exe is in the Server location seen above, you can run the following command to execute it.

In command prompt or powershell type the following
cd C:\Program Files\exacqVision\Server

Then type:
psmove -r-


Additional Information and KB’s for reference

  1. It defaults to report-only mode. psmove -r- will move files.
  2. It will open a ps file and get the first frame timestamp and determine the correct hour directory for the file, based on the CURRENT timezone. If the file is not in the correct hour directory, it will rename it to put it in the correct directory.
  3. Collision avoidance: If there is already a file in the destination directory of the same name, it will decrement the timestamp by one second, generate the new name and try again. Only the file name is changed, not the file content.
  4. The reporting is still pretty slim. report-only mode when specifying a “path” doesn’t currently count what “would” be moved correctly. When moving, it will count the hours and files that were moved.
  5. The default mode is to check all volumes. It will locate all of the media in the y/m/d/h directories. report-only mode will count correctly.
  6. It does not delete empty files. With newer versions of ev there shouldn’t be any. It will report empty files. An empty file cannot be checked for the correct directory. It’s empty and, therefore; doesn’t have a first frame timestamp.
    So, on a server that recorded in one timezone and then changes timezones, PSmove will get the files in the correct hour directories. All of the content should then be searchable.
  7. We’ve reduced the dependencies to the minimum, there are still dependencies. PSmove will only work with the server for that version and later after the compiler upgrade.

KB’s
https://support.exacq.com/#/knowledge-base/article/12416

PSMOVE.exe file:
https://support.exacq.com/#/file-manager/file/32753166-bddf-41d1-9fbd-a8ae6a9e10b4/psmove-exe

We will continue to update this KB as the Linux version gets finalized.

<br>

Categories
Video Library Highlighted Video Guides Installation exacqVision Server Youtube Video Library Categories Products

exacqVision System Licensing

This video will walk new system installers and users through several methods available to apply license keys their exacqVision VMS.<br><br> Chapters:<br> 00:00 Intro<br> 00:20 About License Keys<br> 00:59 exacqVision Advantage<br> 01:25 Method 1 – Import from exacq.com<br> 02:27 Method 2 – Import from Key file<br> 02:58 Method 3 – License Retrieval<br> 03:54 Method 4 – Manual entry<br> 04:17 System Recovery<br> <br>
Categories
Knowledge Support Support exacqVision Server Products

TDVR Capture Card Faulty Board

Description 

There were reports of capture cards working for upwards of 10 minutes and then would fail to produce video in live views. We have identified the issue and made the proper corrections. If this is seen on a system please follow the instructions below to identify if the board is affected. Then take the appropriate steps to set up a RMA with support to get a new card shipped for replacement.

Product 

  • Exacq Servers A and Q series.
  • exacqVision 23.03 up to 24.03

Steps to Reproduce 

If a Capture card is exhibiting these symptoms then please identify the stamp on the card seen below.

These instructions provide step by step procedure for replacing a tDVR analog card in the Q-Series / A-Series Desktop chassis.   Before changing the board, be sure that the system is unplugged from any power source and the system is placed on a clean anti-static surface. Faulty PCB board can be identified by the manufacture marking HTG on the back of the board centered near the top.  Replacement cards will have a CTX marking seen below.

Tools Required:
Phillips Screwdriver
5MM 1/4″ hexdriver

  1.  Remove top cover screws on both side of the chassis.

2. Remove two top cover screws and three card mounting bracket screws.

3. Remove top Cover and pull out tDVR card by pulling straight up.                                                                                                                           

4. Disassemble the mounting bracket from the card by removing two hex nuts.  

5. Attach the replacement card to the bracket and assemble the system by reversing the steps above.

To test the new board, boot the system and open client and verify 16 port display in live view.  

Solution

We found that a component was change during manufacturing which was found to be faulty and we have the proper components now that have been validated and working.

Categories
Plugin Knowledge Support Support exacqVision Server Products SamsungPI

Samsung PNM-C34404RQPZ Connection Issues

Description 

There have been several reports of connection issues with the Samsung PNM-C34404RQPZ. Reports of the units rebooting upon connecting it to the client and which plugin to utilize.


Product 

Exacq Server 24.03.7.0
Camera Info: Samsung PNM-C34404RQPZ
FW used: 23.01.04_20240417_R650

https://www.exacq.com/integration/ipcams/#getCameraRecord=901b747e-fcbf-5464-7543-5aeb7ae3afe8~nstep_id=step-3

Steps to Reproduce 

In the Client go to Add IP Cameras under the configuration. Add the first set of fixed camera’s as you would normally do for any camera.
Add the PTZ camera using the method seen below with the override.

Expected Results 

Camera should connect and work as designed.

Actual Results 

Some reports experience the camera rebooting during connection due to the none use of the power supply that is shipped with the unit. The Power supply must be used.

When connecting the camera as Hanwha or Samsung Plugin on older FW 23.01.03_20240119_R528 will connect but it was reported that motion was not working.

Solution

Update Exacq Server to 24.03.7.0 or above.
Use FirmWare 23.01.04_20240417_R650.
Add PTZ sensor manually using ipaddress#bank=2
Add the camera as Hanwha or Samsung device type.
Make sure the power adapter is of correct specification for proper functioning of the camera. Refer to the camera data sheet.


NOTE:
We have noticed Hanwha has started changing the gov size down to the framerate when users lower the framerate, but not the other way around.

If a user attempts to change a setting while the HTTPS connection is still being attempted, the camera has trouble sending data.

To check this, Log Into the camera web page and verify the GOV size is set to frame rate or higher. Out of the box they are set to 2x framerate. For example- 30fps 60GOV.

AES-878

Categories
exacqVision Server Windows Knowledge Support Support exacqVision Server Products PanasonicPI

H265 Motion Detection Fails on Panasonic WV-S8531N

Description 

The Panasonic WV-S8531N fails to detect motion when using H265 option.

Product 

ExacqVision Server

  • Server 22.09

Steps to Reproduce 

  • Connect the Camera to Server 22.09 using camera FW 1.03 and set the schedule to record motion.
  • Set Camera to Motion recording schedule and use H265 Format.

Expected Results 

Motion is detected and video records.

Actual Results 

Motion is not detected and video is not recorded.

Solution

Updating firmware to S8531_202ES allowed the camera use Motion with H265 format on Server 22.09.

AES-146

<br>

Categories
exacqVision Server Windows Knowledge Support Support exacqVision Client exacqVision Server Products

Video Loss on Live View TDVR Capture Card

Description 

Reports of 23.09.9.0 Server would cause the Capture Card to show video loss on live page. This was not affecting video recording as live and recorded video were searchable.

Product 

  • Server 20.09.9.0

Steps to Reproduce 

Update server from server version prior to 23.09.9.0

Expected Results 

Should not show video loss.

Actual Results 

Live view would show video loss.

Solution

Update to Server Version 24.03.7.0

<br>

Categories
Knowledge Support Support exacqVision Server Products

“Needs Prep” Seen On Hardware or Volume tabs

Description 

A few Customers have seen Needs Prep in the Exacq Client on the Storage Page under Volume and Hardware. The Drive Tab drives will all show healthy. The only issue seen is a false negative indicating that the Unit 1 c0/v0 shows “Needs Prep”, seen below. None of the drives listed under Unit 1 will indicate any issue and show up as healthy.

The Volume tab on the Storage page will also show that the volume “Needs Prep” and is only cosmetic.

Product 

exacqVision Server versions 23.09.9.0 and 24.03

Steps to Reproduce 

Update exacqVision Server to versions 23.09.9.0 or 24.03. The Hardware tab and Volume tab will show the Status “Needs Prep”.

Expected Results 

Drive Status is “Healthy”.
“Needs Prep” should not be shown unless the drive needs to be prepped or formatted for newly added drives.

Actual Results 

Needs Prep is displayed on Volume tab and the Unit under the Hardware tab.

Solution

If a this issue is seen, update exacqVision Server to version 24.03.7.0.

AES-849