board *** watchdog expired Description The heartbeat communication to the capture board has timeout. The system will reboot. Notes Could be a hardware problem or anti-virus interference. Also possible if no page file is enabled.
Category: StretchPI
board *** get supported standards error ***
board *** get supported standards error *** Description Communication could not be established to the Stretch board. Notes Could be firmware or hardware related.
board 0 set date time error SDVR_ERR_BOARD_NOT_CONNECTED
board 0 set date time error SDVR_ERR_BOARD_NOT_CONNECTED Description The Capture Board was not found. Notes This can be a problem with the Capture Board driver, the PCI slot, or the physical Board itself.
board 0 get config error SDVR_DRV_ERR_MSG_RECV
board 0 get config error SDVR_DRV_ERR_MSG_RECV Description An error message was received when the software tried to connect to the Capture Board. Notes This can be a problem with the Capture Board driver, the PCI slot, or the physical Board itself.
board 0 temperature is XX.X degrees C
board 0 temperature is XX.X degrees C Description This is the temperature of the Capture Board. Notes This log will only show if the current temperature is above the Temperature Monitor Threshold set on the Device configuration page. The default threshold is 85.