Invalid incoming alarm XML.
Description
The config XMl may be corrupt.
Notes
Reload previously exported config or delete and let the plugin recreate a new one.
Invalid incoming alarm XML.
The config XMl may be corrupt.
Reload previously exported config or delete and let the plugin recreate a new one.
Invalid config update XML.
The config XML may be corrupt.
Reload previously exported config or delete and let the plugin recreate a new one.
Allocation failure while processing *** XML.
Insufficient resources when attempting to update the config XML.
The root drive may be full or anti-virus may be interfering.
*** socket error 113
No route to host. Destination unreachable (ICMP). This error occurs when an ICMP destination unreachable packet for the socket is received.
Likely to be a Linux server. There is a network problem of some kind.
*** Socket receive timeout ***.
Communication dropped to device.
Likely network related.
*** Socket Exception – Waiting on reconnect timeout.
This is a generic message indicating that a communication socket closed unexpectedly.
Could be related to network issues, or anti-virus.
Request failed – Check your credentials.
Bad username/password.
RTSP Connection timeout detected. Attempting to reconnect.
The RTSP stream timed out and is no longer sending frames for a period of at least 10 seconds.
Request was denied by the device. Make sure the correct credentials have been entered.
Bad username/password.
Discarding frame of excessive length ***
A frame received, exceeded the available buffer space for the camera plugin.
The buffer for individual plugins has changed over time. Check the release notes. It’s possible the customer may need to update to a newer version of Server to support a newer camera with larger frames.
%BR%%BR%
For instance: %BR%
exacqVision Server 5.1.3.34360 increased frame buffers to 2MB for larger megapixel cameras%BR%
<br>