Failed to poll socket read/write status – WSAEFAULT. Failed to poll socket read/write status – WSAENOTSOCK

Failed to poll socket read/write status – WSAEFAULT. Failed to poll socket read/write status – WSAENOTSOCK Description In exacqVision Server 6.7.30, 6.7.31, and 6.8.1, the server will become unusable and the system might enter a reboot cycle if 63 or more clients are connected to the server at the same time. The server will log… Continue reading Failed to poll socket read/write status – WSAEFAULT. Failed to poll socket read/write status – WSAENOTSOCK

Request was denied by the device. Make sure the correct credentials have been entered

Request was denied by the device. Make sure the correct credentials have been entered Description With Axis firmware 5.70 and later with encryption mode enabled, an Axis device could take up to five minutes (the default setting for IP reconnection in exacqVision) to start streaming. Notes Workaround: Wait for the IP reconnection period to elapse… Continue reading Request was denied by the device. Make sure the correct credentials have been entered

*** – only enterprise systems allow directory integration.

*** – only enterprise systems allow directory integration. Description The current license key is Start or Professional, but the current configuration is trying to use LDAP. Notes This can happen if a Start/Professional license is applied to a previously Enterprise system. Or if the exacqVision Client is attempting to use SSO to connect to a… Continue reading *** – only enterprise systems allow directory integration.