Description
Kantech Connection will not stay connected on Exacq Server Version 22.09.2.0. The connection will only stay connected for 5 seconds and then it disconnects.
Product
Exacq Server 22.09.2.0
Reported on Kantech 8.30.05 and 8.50.
Steps to Reproduce
- Update server to 22.09.2.0
- Check connection status in integration page and integration will disconnect.
Expected Results
Integration should remain connected
Actual Results
Integration connection status changes to Disconnected.
Solution
Update to Build 22.09.1628700.0 or wait for December 2022 Release.
AES-71