Categories
Video Library Configuration Knowledge Support Support Illustra Youtube Video Library Categories Products exacqVision Integrations

Illustra Body Worn Camera Setup (Legacy) – Support Training

IMPORTANT: This video was made for BWC Kiosk Software version 1.x and was deprecated upon release of version 2.x

This video is for internal support training and includes Troubleshooting information towards the end, beginning at the 15:00 mark.

<br>

Categories
Knowledge Support Support exacqVision Client Illustra exacqVision Server Categories Products

Preparing Illustra cameras for Network Loss Recording with exacqVision server.

Preparing Illustra cameras for Network Loss Recording with exacqVision server.

Configuration steps for Network Loss Recording recording:

  • Go to the camera’s web page. Under “Event Actions”, check the “Record” option for at least one of the fault action Names.
  • Under Analytics, Client the “Action” dropdown and select the Name you just enabled above.
  • Ensure a Micro SD card is installed to the camera, then go to the Edge recording section. Format the SD card with vfat from the “SD Card Management” tab.
    NOTE: Don’t check the “Encrypt entire contents of the SDcard”
  • In “Record Settings”, Check the box for “Enable Event Record” and select the “Record Source” that exacqVision is currently recording. Set the Pre and Post to 10 seconds.
  • Under “Offline Record Settings”, set the NVR IP address to which the camera is connected, then set the pre and post-seconds.
  • Disconnect and re-connect to the camera in in exacqVision on the “Add IP Cameras” page
  • To confirm that the camera is now storing recordings for exacqVision to request, (back in the camera’s web GUI) go to the Event Download tab. Confirm that there is a new file with the appropriate time stamps..

Note: There must be motion during the downtime to have the camera record to the SD card. The resulting file will be requested by exacqVision after re-connection.

Note:Network loss recording will not be triggered on a Server restart only motion can be triggered for this event.

Categories
Knowledge Support Support exacqVision Client exacqVision Server Categories Products

TCP Listener not showing “Connected”

When adding an IP Serial Port, most of the time you will see the Status go to “Connected”

However, the Type “TCP Listener” does not actually connect to the device sending data. We are simply opening up on that port and waiting for any unencrypted data to show up.

Because of this the Status will remain “Connecting” indefinitely. This is the expected behavior.

This also means the Port Status of the Serial Profile will show “Connecting” as well.

Categories
Configuration Cloudvue Video Library Cloudvue Access Control Youtube Video Library Categories Products

Cloudvue Access Control Subscriptions for Cloudvue Partners

This video explains where to change Cloudvue account subscription settings for access control, as well as the differences between the various subscription types so that Cloudvue Partners, dealers, and integrators will know which ones their clients will need.
Categories
Video Library Cloudvue Cloudvue Access Control Marketing Youtube Video Library Categories Products

Cloudvue Access Control Subscriptions for Customers

Cloudvue hosted access control offers your sites options for hardware installation, but there are also different subscription types you may want to know about so you are prepared when discussing with your Cloudvue Partner, dealer, or integrator. This video explains where to view your Subscription settings as well as the features each subscription type provides.
Categories
Sales Materials Case Studies Cloudvue Documentation Cloudvue Access Control Categories Products

Test Case Studies

Categories
Knowledge Support Support exacqVision Server Categories

Error Code 49: Invalid Credentials When Logging Into LSA (LSI Storage Authority)

Description 

LSI Storage Authority (LSA) fully supports English OS only, other languages are supported but a change to the LSA.conf file is necessary before you can login to LSA.

Product 

  • MegaRAID
  • LSI Storage Authority (LSA)

Steps to Reproduce 

  • Launch LSA from the desktop 
  • Enter the administrators username and password

Expected Results 

  • Login is successful and the LSI Storage Authority Landing Page is displayed

Actual Results 

  • Login fails with Error Code 49: Invalid Credentials

Solution

LSA fully supports English OS only.If you are using native German, French or Spanish OS, you need to edit the LSA.conf file and translate “Administrators” to your native language.
Resolve Error Code 49: Invalid Credentials with the following steps:

  • Stop the exacqVision Server Service
  • Stop the LSAService Service
  • Edit LSA config file (LSA.conf)
    • C:\Program Files(x86)\LSI\LSIStorageAuthority\conf\LSA.conf
    • Locate this line:  full_access_groups = Administrators
    • Depending on the OS language change the key word Administrators to  Administrateurs (French) Administratoren (German) or Administradores (Spanish)
      • French
        • full_access_groups = Administrateurs
      • German
        • full_access_groups = Administratoren
      • Spanish
        • full_access_groups = Administradores
      • Russian
        • full_access_groups = Администраторы or Administratory
    • Save the changes
  • Start the LSAService Service
  • Start exacqVision Server Service

Source: Broadcom Knowledge Base Article 1211236746276

Error-Code-49-Invalid-Credentials-when-trying-to-login-to-LSA-management-software.pdf
Categories
exacqVision Server

Arecont cameras are not recording motion on server version 22.12

Description:

Arecont cameras are not recording motion, and the motion tab is not showing on the cameras settings page

The name of the camera is changing to AVCoster-Contera

Resolution:

The fix for the issue has been implemented on Version 22.12.115

you can download the Server from the links below

Windows 64bit

https://support.exacq.com/#/file-manager/file/51aeec4a-1fd0-46e1-8e54-05343684e274/exacq-vision-server-22-12-115-0-x64-exe

Ubuntu 64bit

https://support.exacq.com/#/file-manager/file/1e73f452-bd4e-484a-a52a-aa60a06def9a/exacq-vision-server-22-12-115-0-x64-deb

Windows 32bit

https://support.exacq.com/#/file-manager/file/ec32127e-3c76-474d-a1da-839a2b615cc9/exacq-vision-server-22-12-115-0-x86-exe

Ubuntu 32bit

https://support.exacq.com/#/file-manager/file/c31c6c95-2422-4fa8-b637-a438ca842a34/exacq-vision-server-22-12-115-0-x86-deb

Categories
Knowledge Support Support exacqVision Server

Analog PTZ Presets Are Not Saving for Customrole Users

Description 

Customrole users with appropriate privileges can create analog ptz presets and while they appear to save are not available in Live.

Product 

exacqVision Server v22.09 and 22.12

Steps to Reproduce 

  • exacqVision Client > Configuration > Users
  • select an existing customrole user or create one ensuring User View PTZ Preset Admin options are enabled
  • Close and re-open the client, logging in using the customrole user
  • Select an analog PTZ camera in Live
  • Right click and select Create PTZ Preset
  • Enter a Preset Name, click OK
  • Again Right Click on the Live Image
  • Select PTZ

Expected Results 

  • The PTZ preset just created is listed and available for selection

Actual Results 

  • The PTZ preset just created is not listed

Solution

exacqVision Server build 22.12.739702.0 is available and the fix will be included in exacqVision Server 23.03
See AES-220 for additional details

Categories
Knowledge Support Support Categories exacqVision Webservice Products

Browser Thin Client Output Trigger Not Staying On

Description 

When you activate the soft trigger on the thin client it stays on for about 10 seconds then turns off and on again automatically.

Product 

  • exacqVision WebServer / Thin Client

Version

Issue was confirmed on 21.12 and 22.09, but may exist on other versions.

Solution

This will be resolved in version 23.03 of the web service
AES-217