Failed to poll socket read/write status – WSAEFAULT. Failed to poll socket read/write status – WSAENOTSOCK

Failed to poll socket read/write status – WSAEFAULT. Failed to poll socket read/write status – WSAENOTSOCK Description In exacqVision Server 6.7.30, 6.7.31, and 6.8.1, the server will become unusable and the system might enter a reboot cycle if 63 or more clients are connected to the server at the same time. The server will log… Continue reading Failed to poll socket read/write status – WSAEFAULT. Failed to poll socket read/write status – WSAENOTSOCK

Request was denied by the device. Make sure the correct credentials have been entered

Request was denied by the device. Make sure the correct credentials have been entered Description With Axis firmware 5.70 and later with encryption mode enabled, an Axis device could take up to five minutes (the default setting for IP reconnection in exacqVision) to start streaming. Notes Workaround: Wait for the IP reconnection period to elapse… Continue reading Request was denied by the device. Make sure the correct credentials have been entered