Installing A-Series Rails on Racks with Threaded Round Holes

The rack mount rails that ship with exacqVision A-Series NVRs are designed to be toolless when used with server racks that have square or unthreaded round mounting holes on the rack uprights. The following guide describes how to adapt these rails, using tools, for use with rack uprights with threaded round screw holes.

  1. Examine the each end of the rail and take note of the pegs, as indicated in the illustration below.
  1. Insert a Phillips-head screwdriver into the slot at the end of each peg and turn to remove the pegs. Repeat this on the opposite end of the rail. The rear end does not have a center peg.
  1. Each end of the rail should have all pegs removed.
  1. Depending on the spacing of the holes on your rack, the L-bracket on the end of the rail may fit around the upright, facing outward, or may need to be placed behind it, as pictured. Here, the screw threads through the rack and then into the threads on the end of the rail where the pegs you removed from previous steps were located. Use installer provided screws to secure the rail to the rack’s upright.

<br>

Categories
Video Library Documentation Quick Start Guides Installation Highlighted Video Guides Youtube Video Library Categories Products exacqVision Hardware

exacqVision A-Series Quick Start Video

The A-Series Network Video Recorders from Exacq provide a versatile range of options and are some of the most popular choices for most users. Choosing the best model for your deployment will be largely based on your storage and configuration needs. This video compares features of A-Series NVR models and steps through unpacking and setup.<br><br>

Chapters:<br>
00:00 Intro<br>
00:15 Unboxing<br>
01:03 Model Comparison<br>
02:06 Port Identification<br>
03:30 Rack Installation<br>
05:18 Hard Drive Installation<br>
06:08 Setup<br>
07:09 Licensing<br>

Related Articles

Installing A-Series Rails on Racks with Threaded Round Holes

<br>

Categories
Documentation Quick Start Guides Categories Products exacqVision Hardware

Installing X-Series ReadyRails on Racks with Threaded Round Holes

The ReadyRails that ship with exacqVision X-Series NVRs are designed to be toolless when used with server racks that have square or unthreaded round mounting holes on the rack uprights. The following guide describes how to adapt these rails, using tools, for use with rack uprights with threaded round screw holes.

  1. Examine the each end of the rail and take note of the pegs, as indicated in the illustration below.
  1. Insert a flathead screwdriver into the slot at the end of each peg and turn to remove the pegs. Repeat this on the opposite end of the rail.
  1. Remove the end plate. Repeat this at the opposite end of the rail.
  1. Fit the L-bracket on the end of the rail around the upright, facing outward. Use installer provided screws to secure the rail to the rack’s upright. Use the bottom of the bracket for front/rear alignment as the bracket holes are in different positions on the front and rear of the rail.

<br>

Categories
Video Library Installation Youtube Video Library Categories Products exacqVision Hardware

exacqVision X-Series Quick Start Video

The X-Series Network Video Recorder from Exacq provides high performance hardware with exacqVision surveillance video management software. All X-Series systems provide hot-swappable hard drives, dual, hot-swappable power supplies and mirrored operating system drives independent of video storage for continuous uptime. This Quick Start Video will introduce you to the X-Series systems and guide you through initial setup.