Public Development
Tag: Level2
Dynamic DNS Request Error 776
Description When setting up the Dynamic DNS feature on exacqISP, integrators with a “Shared” host type utilize multitenancy resulting in EM returning an incorrect domain name which causes error 776. Product Integrator Service Portal Steps to Reproduce Access https://admin.exacq.netFilter by CIDLogin to the customers Integrator Service Portal URL, https://CID.exacq.net/accounts/login/?next=/ where CID is the customers ID… Continue reading Dynamic DNS Request Error 776
Replacing a Drive in Ubuntu 20.04 or later, Using GParted (Legacy)
This procedure is applicable to replacing the primary hard drive of a Linux-based exacqVision system. It assumes that the operating device is installed to an on-board flash device. Do NOT use this procedure when simply adding a drive to a system.
EM not showing camera names and other information
Description When using exacqVision Enterprise Manager version 22.03. Some of the information of servers is not shown even if the user has the correct rights. This may also affect creating users. Product Enterprise Manager 22.03 Steps to Reproduce Add Server to EM Go to Cameras Expected Results All cameras are displayed with all information. Actual… Continue reading EM not showing camera names and other information
Updating the BIOS on Systems with ASRock C236M WS Motherboards
Description The following instructions can be used to update the BIOS on systems with ASRock C326M motherboards. Product Asrock C236M WS Motherboard Instructions Download the C236MWS3.12E flash file HEREFormat a 32MB or larger USB key as FAT32Copy the flash file to the root of the USB keyPlug the USB key into the NVR and restart… Continue reading Updating the BIOS on Systems with ASRock C236M WS Motherboards
Substitute Power Supply Exceeding Voltage Range on 2U Z-Series
Description Manufacturing has had to substitute a power supply which has been observed to exceed the originally specified operating range. Product exacqVision 2U Z-Series Servers Solution To resolve update to exacqVision Server version 22.06.104 or higher available in Artifactory. The allowable voltage range has been changed from 11.4 – 12.6 VDC to 11.1 – 12.9… Continue reading Substitute Power Supply Exceeding Voltage Range on 2U Z-Series
How to Disable/Enable exacqVision Watchdog Timer
Description Built by Exacq “BBE” NVRs utilize a watchdog timer, which during normal operation is reset every second. If the watchdog timer has not been reset within 60 seconds it will trigger a system reboot. The assumption being that machine is in a bad state. For various troubleshooting reasons you may need to disable/enable the… Continue reading How to Disable/Enable exacqVision Watchdog Timer
Error in executing media test (*** query) for status refresh (error ***)
Error in executing media test (*** query) for status refresh (error ***) Description Indicates there is no media in the Servers DVD/CD drive. Notes This message will come up on service start, and if you hit Refresh Status in the Exacq Recall page.This is a normal message if there is no disk in the drive.
*XXX buffer full state = 0 content true
*XXX buffer full state = 0 content true Description Unable to buffer larger than 2MB image size. Older version of Server (pre 8.2) had a smaller buffer for video frames. Notes Update beyond 8.2, or reduce either the quality or record resolution.
Exacq Enterprise manager services on windows are not starting
Issue If Exacq Enterprise Manager services on Windows are not starting and giving this message Usually, it’s going to be a user privileges issue, and the user that is used for running the service is not able to start it Solution Sometimes in the domain environment, the service users will be restricted and will not… Continue reading Exacq Enterprise manager services on windows are not starting