System watchdog after changing time on an Una

Una systems may watchdog after changing the system clock backwards.

To disable usbdio watchdogs, add this to usbdio.ini:

watchdog=0

If Una is the 16 port version, the above line will need to be added to both device sections in usbdio.ini.